- Excavator steering system anatomy training desk
- Hydraulic front hanging mechanical experimental device
- Water pump performance experimental device
- Contact oxidation pool training desk
- Drinking water treatment process training desk
- Reverse osmosis membrane training
- Softness and salt removal experimental device
- Salvation tank experimental device
- Aerobic biological treatment training device
- Bio -turntable principle experimental device
- Lucky ratio blocking test device
- Socci condiment training desk
- Industrial wastewater treatment training desk
- Industrial wastewater treatment process simulation experimental device
- CNC milling machine installation and maintenance training table
- CNC Machining Center Maintenance and Processing Technical Experimental Desk
- AC Voltage Merragatory System Electrical Experiment Device
- Solar power generation experimental device
- Electrical experimental device of ship anchor machine
- Worker Electrical Engineering Technology Training Device
WeChat:18058325687
Phone:18058325687
WhatsApp:18058325687
Address:Shanghai Industrial Park, Jiading District, Shanghai
ZOPDLX-03 Change Duty Electric Skills Training Device
The power training device of the power distribution room on duty, the electrical training system of the substation is based on the 35kV substation as the system model, using some typical, commonly used real components and system simulation control screens. High and low voltage electrical appliances and complete equipment in the electric chamber.
As China's large and medium-sized enterprises increase year by year, the electric power industry develops rapidly, the demand for electricians continues to increase, and there is a shortage of electricians on duty in power transformation and distribution rooms; the "Skills Tr*ning and Assessment System for Electricians on Duty in Power Transformation and Distribution Rooms" is to cooperate with the assessment of electricians on duty in power transformation and distribution rooms , based on the "Occupational Standards for Electricians on Duty in Transformer and Distribution Rooms" of the Ministry of Labor and Social Security, with reference to relevant vocational skills compiled by the Ministry of Labor and Social Security, the Electric Power Industry Vocational Skills Appr*sal Guidance Center, the Machinery Industry Vocational Skills Appr*sal Guidance Center, and the Electric Power Department of the Ministry of Energy. Appr*sal guide, tr*ning syllabus, tr*ning materials, and question bank are developed. This system uses a 35KV substation as a primary system model , using some typical and commonly used primary real components combined with a system simulation control panel. The tr*ning project involves high and low voltage electrical appliances and complete sets of equipment in the power transformation and distribution room, monitoring and meter reading, Power relays and relay protection, switching operations, typical low-voltage electrical lines, etc. can be used as practical tr*ning equipment for students in power supply and distribution majors and related majors in vocational schools and technical schools, and as a tr*ning and assessment platform for electricians on duty in power transformation and distribution rooms.
2. Characteristics
1. The primary system uses typical real components commonly used in the field, and strives to create a real environment for professional positions;
2. The primary system wiring is typical and rich, and can simulate switching operations under various requirements;
3. The practical tr*ning items are complete and can better meet the requirements of tr*ning assessment and appr*sal.
3. Technical performance
1. Input power: three-phase five-wire ~ 380V±10% 50HZ
2. Capacity:<5kVA
3. Working environment: temperature -10℃~+40℃, relative humidity <85% (25℃), altitude <4000m
4. Practical tr*ning projects
Cognition and operation of high and low voltage switches and complete sets of equipment
Cognition and operation of 1.10kV high-voltage isolation switch
Cognition and operation of 2.10kV high voltage vacuum circuit breaker
Cognition and operation of 3.10kV high-voltage switchgear
4. Cognition and operation of HD13 low-voltage knife switch
5. Cognition and operation of DW15 low-voltage universal circuit breaker
6. Cognition and operation of low-voltage molded case circuit breakers
Cognition and operation of 7.0.4kV low voltage switchgear
Cognition and wiring of high and low voltage current and voltage transformers
8. Understanding and wiring of high and low voltage current transformers
9. Understanding and wiring of high and low voltage voltage transformers
Structural understanding and characteristic testing of power relays
10. Characteristics of current relays
11.Characteristics of voltage relay
12. Characteristics of intermediate relays
13.Characteristics of time relay
14.Characteristics of flash relay
15.Characteristics of inverse time relay
Power supply and distribution system relay protection
16. Wiring and debugging of time-limited overcurrent protection circuit for power supply lines
17. Wiring and debugging of low voltage starting overcurrent protection circuit of power supply line
18. Wiring and debugging of the current quick-break protection circuit of the power supply line
19. Wiring and debugging of power supply line current inverse time overcurrent protection circuit
20. Wiring and debugging of distribution transformer overcurrent protection circuit
21. Wiring and debugging of current quick-break protection circuit of distribution transformer
22. Wiring and debugging of overload protection circuit of distribution transformer
23. Simulated over-temperature protection of transformer
Secondary circuits and automatic devices of power supply and distribution systems
24. Control and signal circuit of circuit breaker
Insulation monitoring device circuit for 25.6~35KV system
26. One-time reclosing of power supply and distribution system
27. Integrated line overcurrent protection and automatic reclosing
28. Power factor compensation
35kV substation monitoring and meter reading
29.Use and parameter setting of three-phase multi-function intelligent meter
30. Use and parameter setting of intelligent temperature and humidity controller
31. System operating status monitoring
32.35kV dual incoming line power monitoring
33.35kV substation m*n transformer power monitoring
35kV substation switching operation
34. System operation mode switching and switching operation
35. Line switching operation during power outage
36. Line power transmission and switching operation
37. Switching operation from two incoming lines to one line power supply
38. Switching operation from one incoming line power supply to two lines of power supply
39. Dual bus operating status switching operation
40. Segmented single bus operating status switching operation
41. Busbar changes from running state to m*ntenance switching operation
42. Busbar changes from m*ntenance status to running switching operation
43.Transformer from running state to m*ntenance switching operation
44.Transformer switching operation from m*ntenance status to operation
45. Transformer changes from running state to cold standby switching operation
46. Transformer changes from running state to hot standby switching operation
47.Transformer switching operation from cold standby to running operation
48.Transformer transfer from hot standby state to running switching operation
49. The outlet switch changes from running state to m*ntenance switching operation.
50. Outgoing line changes from m*ntenance status to cold standby switching operation
51. Outgoing line switching operation from cold standby to hot standby
52. Outgoing line switching operation from hot standby to running
53. Outgoing line switching operation from m*ntenance to operation
54. Wiring and debugging of typical low-voltage electrical lines
Recommended products: Hydraulic test bench
- Previous:ZOPDL-WJ Electric Power System Microcarmark Protection Training Device
- Next:ZOPDJ-CZ motor disassembly experimental device