Product
News
- Excavator steering system anatomy training desk
- Hydraulic front hanging mechanical experimental device
- Water pump performance experimental device
- Contact oxidation pool training desk
- Drinking water treatment process training desk
- Reverse osmosis membrane training
- Softness and salt removal experimental device
- Salvation tank experimental device
- Aerobic biological treatment training device
- Bio -turntable principle experimental device
- Lucky ratio blocking test device
- Socci condiment training desk
- Industrial wastewater treatment training desk
- Industrial wastewater treatment process simulation experimental device
- CNC milling machine installation and maintenance training table
- CNC Machining Center Maintenance and Processing Technical Experimental Desk
- AC Voltage Merragatory System Electrical Experiment Device
- Solar power generation experimental device
- Electrical experimental device of ship anchor machine
- Worker Electrical Engineering Technology Training Device
Contact us
WeChat:18058325687
Phone:18058325687
WhatsApp:18058325687
Address:Shanghai Industrial Park, Jiading District, Shanghai
Chemical Fluid
zopHGRG-53 gas meter calibration training platform
Gas meter calibration test bench, gas meter calibration training device, gas meter multi-blade blower, turbine flowmeter, venturi flowmeter with differential pressure sensor, orifice flowmeter with differential pressure sensor, various pipeline pressure sensors, gas meter, temperature sensor.
Experimental purpose:
Use turbine flowmeter, Venturi flowmeter, orifice flowmeter to perform actual calibration of gas meters.
M*n configuration:
gas meter, multi-vane blower turbine flowmeter, Venturi flowmeter with differential pressure sensor , orifice flowmeter with differential pressure sensor, pressure sensors for each pipeline, gas meter, temperature sensor, 8-way universal signal input inspection The instrument detects pressure, flow pressure difference, flow rate, and temperature; distribution box. St*nless steel pipelines, regulating valves, data communication and data processing software.
Technical parameters:
1. Input power supply: single-phase AC220V±10% 50Hz, power 800W.
2. Dry gas flowmeter has an accuracy of 2.5% and a rated flow rate of 4m3/h; ±3000Pa U-shaped pressure gauge.
3. Standard flowmeter: turbine flowmeter, orifice flowmeter, Venturi flowmeter, diameter DN25mm, test accuracy 1.0%.
4. *r vortex pump: *r volume 55 m3/h, *r pressure 120mmH2O, efficiency 66%, shaft power 0.37KW.
5. Differential pressure sensor 10 kPa, accuracy 0.25%.
6. Temperature measurement resolution: 0.1℃, measurement accuracy 0.2℃.
7. The 16-point universal signal input inspection instrument measures all experimental measurement parameters such as temperature, resistance, flow rate, and power.
8. Dimensions: 11800×500×1700mm. The shape is a st*nless steel movable bracket with double brake wheels.
9. Virtual simulation software for electrical installation of building buildings and smart buildings. Based on unity3d design, users can choose different interactive interface sizes according to computer configuration, and six levels of image quality are av*lable. The model in the software can be rotated 360°, enlarged, reduced, and translated. There are assistant prompts during the use of the software, and the content is as follows: A. Wet alarm system 1. System overview: Overview of wet alarm system 2. Equipment awareness: equipped with the best viewing angle, equipment det*ls (displaying the introduction or parameters of the equipment), and exercises (Built-in 6 multiple-choice questions, prompts for correct and incorrect choices), schematic diagram (can be entered into the device from the schematic diagram). Equipment includes: nozzle, water flow indicator, signal butterfly valve, exhaust valve, fire alarm control, high pipe pressure gauge, high water tank, Wia control cabinet, pressure stabilizing tank, flow switch, terminal water testing device, dr*nage facilities, water pump connection alarms, hydraulic alarms, delayers, wet alarms, butterfly valves, check valves, fire pumps, safety pressure regulators, and fire pools. 3. Principle display: Show the working principle of the wet alarm system, three-dimensional animation demonstration, the three-dimensional model is translucent, and the internal water flow can be seen. Equipped with a practice module (built-in 4 multiple-choice questions, with prompts for correct and incorrect choices) 4. Design layout: There are multiple-choice questions and calculation questions, each question is scored, and the correct answer and score will be displayed after submission B. Gas fire extinguishing system 1. System overview: Overview of gas fire extinguishing system 2. Equipment awareness: equipped with the best viewing angle, equipment det*ls (displaying the introduction or parameters of the equipment), exercises (built-in 8 multiple-choice questions, with prompts for correct and incorrect choices), Schematic diagram (access to the device from the schematic diagram). Equipment includes: nozzle, HFC-227 storage bottle, bottle head valve, heptafluoropropane one-way valve, high-pressure hose, gas one-way valve, safety valve, weighing alarm, electromagnetic starter, selection valve, smoke alarm, fire Alarm controller. 3. Principle display: Show the working principle of the gas fire extinguishing system, three-dimensional animation demonstration, the three-dimensional model is translucent, and the internal gas can be seen. Equipped with a practice module (built-in 3 multiple-choice questions, with prompts for both correct and incorrect choices) 4. Design and layout: There are 6 multiple-choice questions, each question is scored, and the correct answer and score will be displayed after submission. C. Escape drill: adopted Teaching is conducted in the form of fun games. Escape from the burning room within a limited time. If you make a wrong choice, you will directly enter the score interface.
Use turbine flowmeter, Venturi flowmeter, orifice flowmeter to perform actual calibration of gas meters.
M*n configuration:
gas meter, multi-vane blower turbine flowmeter, Venturi flowmeter with differential pressure sensor , orifice flowmeter with differential pressure sensor, pressure sensors for each pipeline, gas meter, temperature sensor, 8-way universal signal input inspection The instrument detects pressure, flow pressure difference, flow rate, and temperature; distribution box. St*nless steel pipelines, regulating valves, data communication and data processing software.
Technical parameters:
1. Input power supply: single-phase AC220V±10% 50Hz, power 800W.
2. Dry gas flowmeter has an accuracy of 2.5% and a rated flow rate of 4m3/h; ±3000Pa U-shaped pressure gauge.
3. Standard flowmeter: turbine flowmeter, orifice flowmeter, Venturi flowmeter, diameter DN25mm, test accuracy 1.0%.
4. *r vortex pump: *r volume 55 m3/h, *r pressure 120mmH2O, efficiency 66%, shaft power 0.37KW.
5. Differential pressure sensor 10 kPa, accuracy 0.25%.
6. Temperature measurement resolution: 0.1℃, measurement accuracy 0.2℃.
7. The 16-point universal signal input inspection instrument measures all experimental measurement parameters such as temperature, resistance, flow rate, and power.
8. Dimensions: 11800×500×1700mm. The shape is a st*nless steel movable bracket with double brake wheels.
9. Virtual simulation software for electrical installation of building buildings and smart buildings. Based on unity3d design, users can choose different interactive interface sizes according to computer configuration, and six levels of image quality are av*lable. The model in the software can be rotated 360°, enlarged, reduced, and translated. There are assistant prompts during the use of the software, and the content is as follows: A. Wet alarm system 1. System overview: Overview of wet alarm system 2. Equipment awareness: equipped with the best viewing angle, equipment det*ls (displaying the introduction or parameters of the equipment), and exercises (Built-in 6 multiple-choice questions, prompts for correct and incorrect choices), schematic diagram (can be entered into the device from the schematic diagram). Equipment includes: nozzle, water flow indicator, signal butterfly valve, exhaust valve, fire alarm control, high pipe pressure gauge, high water tank, Wia control cabinet, pressure stabilizing tank, flow switch, terminal water testing device, dr*nage facilities, water pump connection alarms, hydraulic alarms, delayers, wet alarms, butterfly valves, check valves, fire pumps, safety pressure regulators, and fire pools. 3. Principle display: Show the working principle of the wet alarm system, three-dimensional animation demonstration, the three-dimensional model is translucent, and the internal water flow can be seen. Equipped with a practice module (built-in 4 multiple-choice questions, with prompts for correct and incorrect choices) 4. Design layout: There are multiple-choice questions and calculation questions, each question is scored, and the correct answer and score will be displayed after submission B. Gas fire extinguishing system 1. System overview: Overview of gas fire extinguishing system 2. Equipment awareness: equipped with the best viewing angle, equipment det*ls (displaying the introduction or parameters of the equipment), exercises (built-in 8 multiple-choice questions, with prompts for correct and incorrect choices), Schematic diagram (access to the device from the schematic diagram). Equipment includes: nozzle, HFC-227 storage bottle, bottle head valve, heptafluoropropane one-way valve, high-pressure hose, gas one-way valve, safety valve, weighing alarm, electromagnetic starter, selection valve, smoke alarm, fire Alarm controller. 3. Principle display: Show the working principle of the gas fire extinguishing system, three-dimensional animation demonstration, the three-dimensional model is translucent, and the internal gas can be seen. Equipped with a practice module (built-in 3 multiple-choice questions, with prompts for both correct and incorrect choices) 4. Design and layout: There are 6 multiple-choice questions, each question is scored, and the correct answer and score will be displayed after submission. C. Escape drill: adopted Teaching is conducted in the form of fun games. Escape from the burning room within a limited time. If you make a wrong choice, you will directly enter the score interface.
- Previous:zopHFRG-54 gas calorific value training platform