- Excavator steering system anatomy training desk
- Hydraulic front hanging mechanical experimental device
- Water pump performance experimental device
- Contact oxidation pool training desk
- Drinking water treatment process training desk
- Reverse osmosis membrane training
- Softness and salt removal experimental device
- Salvation tank experimental device
- Aerobic biological treatment training device
- Bio -turntable principle experimental device
- Lucky ratio blocking test device
- Socci condiment training desk
- Industrial wastewater treatment training desk
- Industrial wastewater treatment process simulation experimental device
- CNC milling machine installation and maintenance training table
- CNC Machining Center Maintenance and Processing Technical Experimental Desk
- AC Voltage Merragatory System Electrical Experiment Device
- Solar power generation experimental device
- Electrical experimental device of ship anchor machine
- Worker Electrical Engineering Technology Training Device
WeChat:18058325687
Phone:18058325687
WhatsApp:18058325687
Address:Shanghai Industrial Park, Jiading District, Shanghai
ZOPDLZD-04 substation comprehensive automation system training device
The comprehensive automation training system of the substation, the 110kV side of the substation simulation experimental device and the 10kV side are used by the single mother segment, and the 35kV side uses a single mother segment to bring the parent wiring. All secondary parts use micro -model relay protection devices and measurement and control devices.
The system consists of three parts: primary system screen, secondary protection cabinet, and substation background system. The primary system uses a typical 110kV substation project as a model . There are two m*n transformers, both of which are on-load voltage regulation types. There are two incoming lines. The 110kV side and the 10kV side use single bus sections, and the 35kV side uses single bus sections. Side bus wiring. The secondary part all adopts microcomputer-type relay protection devices and measurement and control devices, which are divided into four protection cabinets for installation; it can upload data and accept commands from the monitoring host, fully meeting the requirements of "four remote" functions and telecontrol. At the same time, multiple serial port cards are used to effectively solve the communication bottleneck problem between the protection device and the background system.
2. Characteristics
1. Equipped with a typical and complete primary system, the switches and knife gates are operated by different types of switches, and the interlocking settings are complete. Various types of faults can be set in the electrical circuit;
2. The secondary relay protection device is fully configured;
3. The equipment at the bay layer has good performance and reliable operation;
4. The communication system has an independent communication channel to meet the requirements of unattended operation;
5. Good completeness, complete configuration of primary system, secondary system and monitoring system;
6. Strong openness, the protection measurement and control device adopts standard communication protocol, and the software system adopts industrial configuration software and open protocol.
3. Practical tr*ning projects
Line protection class
(1) System normal, **, *** minimum operating mode
(2) Electrical system short circuit
(3) Basic function test of microcomputer protection device
(4) Microcomputer definite time overcurrent protection
(5) Microcomputer time-limited current quick-break protection
(6) Microcomputer with time-limited current quick-break protection
(7) Staged current protection
(8) The influence of operating mode on protection sensitivity and sensitivity verification
(9) Current and voltage ch*n protection
(10) Inverse time limit protection experiment
(11) Staged overcurrent protection and acceleration before automatic reclosing
(12) Staged overcurrent protection and acceleration after automatic reclosing
(13) Power direction overcurrent protection
(14) Zero sequence current protection
(15) Overload protection
(16) Low voltage load shedding
Line design tr*ning (self-design, wiring, action test)
Current and voltage ch*n quick-break protection and over-current protection
Current and voltage ch*n quick-break, over-current comprehensive protection and automatic
Dynamic reclosing
Inverse time current protection and overcurrent protection
Inverse time limit, overcurrent comprehensive protection and automatic reclosing
Current and voltage ch*n protection and acceleration before automatic reclosing
Current and voltage ch*n protection and automatic reclosing acceleration
Inverse time overcurrent and acceleration protection before automatic reclosing
Inverse time overcurrent and acceleration protection after automatic reclosing
Comprehensive line protection
110kV line comprehensive protection (neutral point directly grounded)
35kV line comprehensive protection (neutral point grounded through coil)
10kV line comprehensive protection (neutral point not grounded)
Transformer protection
Normal system operation and measurement of unbalanced current
Analog transformer gas protection
Transformer current quick-break protection
Microcomputer transformer longitudinal differential protection setting
Second harmonic braking experiment of transformer
Transformer differential quick-break protection
Three-winding transformer differential protection
Y/Y-12 double winding transformer differential protection
Y/△-11 double winding transformer differential protection
Study on Ratio Braking Characteristics
Overcurrent protection of double winding transformer
Overcurrent protection of three-winding transformer
Transformer low voltage starting overcurrent protection
Transformer composite voltage starting overcurrent protection
Neutral point directly grounded operating transformer zero sequence protection
Zero-sequence protection of transformer operating with partial neutral point grounded
Overload protection of double winding transformer
Overload protection of three-winding group transformer
Transformer design tr*ning (self-design, wiring, operation test)
Y/△-11 double winding transformer overcurrent protection
Y/△-11 double winding transformer overload protection
Comprehensive protection of double winding transformer
Three-winding transformer comprehensive protection
10kV capacitor bank protection
Three-stage current protection
Overvoltage protection
Low voltage protection
Unbalanced voltage protection
Unbalanced current protection
Zero sequence current protection
Comprehensive protection of capacitor banks
automatic device
Automatic reclosing (front acceleration, rear acceleration, synchronization check, no pressure check)
The backup power supply is automatically turned on (incoming line backup, bus tie backup)
Automatic voltage and reactive power control (implemented by background software)
A system shutdown operation
Substation integrated automation system
- Previous:ZOPLR-508 Air Conditioning Maintenance Debting Training Device
- Next:ZOPDG-JT ship electrical skills basic training device